Browse Source

Paper update

tags/SensorLogger/0.1
Chris Smith 14 years ago
parent
commit
9afbb3dec4
1 changed files with 58 additions and 16 deletions
  1. 58
    16
      papers/project.bib

+ 58
- 16
papers/project.bib View File

@@ -72,6 +72,9 @@
72 72
   pages = {85--89},
73 73
   number = {2},
74 74
   month = {April--June },
75
+  comment = {Android mail milestone in LBSs, LBS originated with E911 mandate.
76
+	Moving LSBs from operator controlled to user controlled major factor
77
+	in success, helped by open systems such as Android and Openmoko.},
75 78
   doi = {10.1109/MPRV.2008.34},
76 79
   file = {Bellavista2008.pdf:Bellavista2008.pdf:PDF},
77 80
   owner = {chris},
@@ -110,6 +113,12 @@
110 113
   booktitle = {European Medical \& Biological Engineering Conference and IFMBE European
111 114
 	Conference on Biomedical Engineering},
112 115
   year = {2005},
116
+  comment = {Mechanism of walking is defined as controlled falling, where the centre
117
+	of gravity oscillates over the supporting limb following an inverted
118
+	pendulum movement. At the end of each pendulum movement, the strike
119
+	of the heel on the floor deaccelerates the swinging phase by generating
120
+	an abrupt vertical acceleration. *Discrete time index, discrete time
121
+	Dirac distribution*. Double integration - walking/stairs.},
113 122
   file = {Caros2005.pdf:Caros2005.pdf:PDF},
114 123
   owner = {chris},
115 124
   timestamp = {2009.12.01}
@@ -127,14 +136,9 @@
127 136
   pages = {32--41},
128 137
   number = {2},
129 138
   month = {April--June },
130
-  comment = {Requirements, general architecture, privacy - audio.
131
-	
132
-	
133
-	Structured prediction - temporal/structure & activity/context dependencies.
134
-	
135
-	
136
-	Difficulties with training (labelling large amount of data); semi-supervised
137
-	training},
139
+  comment = {Requirements, general architecture, privacy - audio. Structured prediction
140
+	- temporal/structure & activity/context dependencies. Difficulties
141
+	with training (labelling large amount of data); semi-supervised training},
138 142
   doi = {10.1109/MPRV.2008.39},
139 143
   file = {Choudhury2008.pdf:Choudhury2008.pdf:PDF},
140 144
   owner = {chris},
@@ -370,6 +374,45 @@
370 374
   url = {http://dx.doi.org/10.1007/3-540-45809-3_28}
371 375
 }
372 376
 
377
+@ARTICLE{Mathie2004,
378
+  author = {Mathie, M. and Celler, B. and Lovell, N. and Coster, A.},
379
+  title = {Classification of basic daily movements using a triaxial accelerometer},
380
+  journal = {Medical and Biological Engineering and Computing},
381
+  year = {2004},
382
+  volume = {42},
383
+  pages = {679--687},
384
+  number = {5},
385
+  month = {September},
386
+  abstract = {Abstract\ \ A generic framework for the automated classification
387
+	of human movements using an accelerometry monitoring system is introduced.
388
+	The framework was structured around a binary decision tree in which
389
+	movements were divided into classes and subclasses at different hierarchical
390
+	levels. General distinctions between movements were applied in the
391
+	top levels, and successively more detailed subclassifications were
392
+	made in the lower levels of the tree. The structure was modular and
393
+	flexible: parts of the tree could be reordered, pruned or extended,
394
+	without the remainder of the tree being affected. This framework
395
+	was used to develop a classifier to identify basic movements from
396
+	the signals obtained from a single, waist-mounted triaxial accelerometer.
397
+	The movements were first divided into activity and rest. The activities
398
+	were classified as falls, walking, transition between postural orientations,
399
+	or other movement. The postural orientations during rest were classified
400
+	as sitting, standing or lying. In controlled laboratory studies in
401
+	which 26 normal, healthy subjects carried out a set of basic movements,
402
+	the sensitivity of every classification exceeded 87\%, and the specificity
403
+	exceeded 94\%; the overall accuracy of the system, measured as the
404
+	number of correct classifications across all levels of the hierarchy,
405
+	was a sensitivity of 97.7\% and a specificity of 98.7\% over a data
406
+	set of 1309 movements.},
407
+  citeulike-article-id = {4636969},
408
+  citeulike-linkout-0 = {http://dx.doi.org/10.1007/BF02347551},
409
+  citeulike-linkout-1 = {http://www.springerlink.com/content/wm35501wq8352865},
410
+  day = {12},
411
+  doi = {10.1007/BF02347551},
412
+  posted-at = {2009-05-26 20:42:51},
413
+  url = {http://dx.doi.org/10.1007/BF02347551}
414
+}
415
+
373 416
 @INPROCEEDINGS{Maurer2006,
374 417
   author = {Maurer, U. and Rowe, A. and Smailagic, A. and Siewiorek, D.P.},
375 418
   title = {eWatch: a wearable sensor and notification platform},
@@ -761,13 +804,12 @@
761 804
 
762 805
 @comment{jabref-meta: groupstree:
763 806
 0 AllEntriesGroup:;
764
-1 ExplicitGroup:Unread\;0\;Abowd1997\;Bellavista2008\;Bellotti2008\;Ca
765
-ros2005\;Davies2008\;Dornbush2005\;Eagle2004\;Floreen2008\;Garakani200
766
-9\;Hein2008\;Lee2007\;Lester2006\;Liao2007\;Liao2007a\;Lukowicz2002\;M
767
-ahdaviani2007\;Maurer2006\;Miluzzo2009\;Nicolai2006\;Parkka2006\;Patte
768
-rson2004\;Philipose2003\;Philipose2003a\;Philipose2004\;Rudstroem2004\
769
-;Schapire1999\;Schilit1994\;Schmidt1999\;Schmidt2008\;Serugendo2008\;S
770
-hen2004\;Song2005\;Stiefmeier2008\;Tentori2008\;Voida2002\;Wang2009\;W
771
-yatt2007\;Yang2008\;;
807
+1 ExplicitGroup:Unread\;0\;Abowd1997\;Bellotti2008\;Dornbush2005\;Eagl
808
+e2004\;Floreen2008\;Garakani2009\;Hein2008\;Lee2007\;Lester2006\;Liao2
809
+007\;Liao2007a\;Lukowicz2002\;Mahdaviani2007\;Mathie2004\;Maurer2006\;
810
+Miluzzo2009\;Nicolai2006\;Parkka2006\;Patterson2004\;Philipose2003\;Ph
811
+ilipose2003a\;Philipose2004\;Rudstroem2004\;Schapire1999\;Schilit1994\
812
+;Schmidt1999\;Schmidt2008\;Shen2004\;Song2005\;Stiefmeier2008\;Tentori
813
+2008\;Voida2002\;Wang2009\;Wyatt2007\;Yang2008\;;
772 814
 }
773 815
 

Loading…
Cancel
Save